Journal of Postgraduate Medicine
 Open access journal indexed with Index Medicus & ISI's SCI  
Users online: 11193  
Home | Subscribe | Feedback | Login 
About Latest Articles Back-Issues Articlesmenu-bullet Search Instructions Online Submission Subscribe Etcetera Contact
 
  NAVIGATE Here 
  Search
 
 :: Next article
 :: Previous article 
 :: Table of Contents
  
 RESOURCE Links
 ::  Similar in PUBMED
 ::  Search Pubmed for
 ::  Search in Google Scholar for
 ::Related articles
 ::  [PDF Not available] *
 ::  Citation Manager
 ::  Access Statistics
 ::  Reader Comments
 ::  Email Alert *
 ::  Add to My List *
* Registration required (free) 


  IN THIS Article
 ::  Introduction
 ::  Clinical material
 ::  Results
 ::  Discussion
 ::  Acknowledgement
 ::  References

 Article Access Statistics
    Viewed7811    
    Printed168    
    Emailed3    
    PDF Downloaded0    
    Comments [Add]    

Recommend this journal


   
Year : 1980  |  Volume : 26  |  Issue : 3  |  Page : 178-180A

Use of indigenous pig pericardial valves for mitral valve replacement.







How to cite this article:
Karbhase J N, Rachmale G G, Panday S R. Use of indigenous pig pericardial valves for mitral valve replacement. J Postgrad Med 1980;26:178-180A


How to cite this URL:
Karbhase J N, Rachmale G G, Panday S R. Use of indigenous pig pericardial valves for mitral valve replacement. J Postgrad Med [serial online] 1980 [cited 2023 Jun 10];26:178-180A. Available from: https://www.jpgmonline.com/text.asp?1980/26/3/178/964




  ::   Introduction Top

In recent years great advances have been made in the designing and application of prosthetic and biological tissue valves. Prosthetic valves have been accepted as the most common valves used for replacement of diseased valves. At present a large variety of these prosthetic valves are available in several shapes and designs[8] each claiming several advantages. But all of them have one common disadvantage that they need life long anti-coagulation.
In India, as in several other Asian countries, the high cost of prosthetic valve and inability to maintain patients on long term anticoagulation poses a very great problem. Early results of frame mounted fascia lata were encouraging.[4], [5] However, in 1972 it became evident that autologous fascia lata valves were totally unacceptable in atrioventricular position.[9] We were encouraged by the successful reports of the use of dura mater valves by Zerbini[12] and the pericardial valve by Ionescu et al[7] and Tandon and Ionescu[11] prompted us to design pig pericardial valves locally in our laboratory.
We are presenting here our early experience in 10 patients who have undergone mitral valve replacement using pig pericardial valves, mounted on a locally made valve frame.

  ::   Clinical material Top

Since August 1978, glutaraldehyde stabilised pericardial xenografts were used for mitral valve replacement. There were seven cases with single valve replacement. In two cases tricuspid annuloplasty was done in addition to mitral valve replacement. One patient underwent triple valve replacement with one of the biological valves that was an indigenous pig pericardial valve.
There were 8 males and 2 females in the series. The age distribution in these patients is shown in [Table 1].
The type of pathology is shown in [Table 2].
The etiology was rheumatic in all cases. In 3 cases there were signs of active rheumatic carditis. All these patients were from low socio-economic status and poorly nourished.
Procuring, mounting and preserving
Pericardium was procured from the slaughter house within half an hour after death of the animal. Following collection a sterile procedure was observed during the entire process of preparation. Pericardial sheets of uniform thickness were selected and were carefully cleaned and trimmed. These sheets were washed with normal saline for five hours. This was an essential step to wash out the soluble proteins which are highly antigenic.
Following this, quadrangular strips measuring 3.2 cms X 1.5 cms are cut. The clean pericardial strips are then stored in 0.5 per cent purified glutaraldehyde buffered to a pH of 7.4 with 0.0067 M phosphate buffer at 4° C for two weeks.
The stent on which the valve is mounted is locally made. It consists of a stainless steel ring covered with a dacron cloth. The sewing rim is made of siliconized rubber covered with dacron cloth. The struts have two holes at their lower end. These holes are necessary to fix the pericardial strip at these points.
Specially designed moulds are used to give an accurate tricuspid shape to the pericardial cylinder and to maintain that shape till mounting of the valve is complete [Fig. 1]. Suturing is done by using 3-0 merselene or 4-0 white merselene suture.
The valve so made is treated with 2% purified glutaraldehyde solution for 48 hours before it is ready for valve replacement.
Operative Technique
In this series all valve replacements were performed by a median sternotomy and conventional cardiopulmonary bypass. The heart was arrested with cold cardioplegia injected in the ascending aorta. Its heat was furher cooled by topical hypothermia. 2-0 prolene continuous suture technique was used to replace the mitral valve. [Fig. 2].

  ::   Results Top

Of the ten patients who underwent surgery, one died on the 4th postoperative day. This patient was an extremely sick boy, aged 11 years, with evidence of rheumatic carditis. The remaining nine patients are well and are regularly followed up at monthly intervals.

  ::   Discussion Top

Pericardial xenograft is a relatively new bioprosthesis. Ionescu's data has already shown that this valve possesses the beneficial characteristics of tissue valve viz. a low rate of post-operative thromboembolism without the use of anticoagulation.[6], [7], [11] Other advantages are avoidance of catastrophic failure, sudden death and haemolysis in patients without a perivalvular leak. The follow up results of our patients are from 3 months to 1 year and our findings are consistent with those of Ionescu's data. The advantage of a very low embolic rate and the absence of valve thrombosis without long term anticoagulation becomes even more significant when considering both the psychological anxieties and the haemorrhagic risks associated with long term anti coagulant therapy.[1],[2],[3],[10]
Improved exercise tolerance, reduction in heart size and symptom-free patients are obviously due to the excellent flow characteristics of this valve. The surface area of the pericardial xenograft available to the flow is significantly larger than those of the frame mounted aortic homografts and heterografts. This is because the aortic annulus which is mounted inside the stent reduces the inner diameter of the aortic homograft or heterograft.
In this small series there was one hospital death. This mortality is comparable to the results reported by other workers using similar or other prosthetic valves.'
The long term results of these indigenously made pig pericardial valves remain to be studied. However, the negligible cost and the absence of thromboembolism without anticoagulation are two main factors which necessitate further interest in these valves.

  ::   Acknowledgement Top

We are thankful to the Research Society of K.E.M. Hospital and Seth G.S. Medical College, Bombay, for financially supporting this research project and allowing its publication.

  ::   References Top

1.Bloomfield, D. K.: Fetal deaths and malformations associated with the use of coumarin derivatives in pregnancy. Amer. J. Obstet. Gynecol., 107: 883-886, 1970.   Back to cited text no. 1    
2.Evans, R. W. Q., Rourke, R. A_. and McGranahan, C.: Thromboembolic complications of anticoagulant withdrawal. Circulation, 37-38 (Suppl. VI), 74, 1968 (Abstract).  Back to cited text no. 2    
3.Gott, V. L., Brawley, R. K. and Michael, Jones: Mitral volve prosthesis problems of thromboembolism. In, "International Symposium on Cardiac Surgery", Edited by Jullio C. Davila, Appleton-Century Crofts, New York, 1977, pp. 395-401.  Back to cited text no. 3    
4.Ionescu, M. 1. and Ross, D. N.: Heart valve replacement with autologous fascia lata. Lancet, 2: 335-388, 1969.  Back to cited text no. 4    
5.Ionescu, M. I., Ross, D. N., Deac Radu and Grimshaw, V. A.: Autologous fascia lata for heart valve replacement, Thorax, 25: 46 56, 1970.  Back to cited text no. 5    
6.Ionescu, M. 1. and Tandon, A. P.: The Ionescu-Shiley pericardial xenograft heart valve. In, "Tissue heart valves", Edited by M. I. Ionescu, Butterworths, London, Boston, Sydney, Wellington, Durban, Toronto, 1979, pp. 203-252.  Back to cited text no. 6    
7.7. Ionescu, M. I . , Tandon, A. P . , Mary, D.A.S. and Abid, A.: Heart valve replacement with the Ionescu-Shiley pericardial xenograft. J. Thorac. Cardiovasc. Surg., 73: 31-41, 1977.  Back to cited text no. 7    
8.Lefrak, E. A. and Starr Albert: Choice of prosthesis. In, "Cardiac valve prosthesis". Edited by Lefrak and Starr. Appleton-Century-Crofts, 1979, pp, 392-400.   Back to cited text no. 8    
9.McEnamy, M. T., Ross, D. N. and Yates, A. K.: Valve failure in seventy-two frame-supported autologous fascia lata mitral valves: Two-year follow-up. J. Thorac. Cardiovasc. Surg., 63: 199-214, 1972.  Back to cited text no. 9    
10.Poller, L. and Thomson, J. M.: Evidence of rebound hypercoagulability after stopping anticoagulants. Lancet, 2: 62-64, 1964.   Back to cited text no. 10    
11.Tandon, A. P. and Ionescu, M. I.: Long term haemodynamic evaluation of aortic pericardial xenograft. Brit. Heart J., 40: 602-604, 1978.  Back to cited text no. 11    
12.Zerbini, E. J.: Results of replacement of cardiac valves by homologous dura mater valves-. Chest, 67: 706-710, 1975.  Back to cited text no. 12    

Top
Print this article  Email this article
Previous article Next article
Online since 12th February '04
© 2004 - Journal of Postgraduate Medicine
Official Publication of the Staff Society of the Seth GS Medical College and KEM Hospital, Mumbai, India
Published by Wolters Kluwer - Medknow