Journal of Postgraduate Medicine
 Open access journal indexed with Index Medicus & ISI's SCI  
Users online: 26330  
Home | Subscribe | Feedback | Login 
About Latest Articles Back-Issues Articlesmenu-bullet Search Instructions Online Submission Subscribe Etcetera Contact
 
  NAVIGATE Here 
  Search
 
 :: Next article
 :: Previous article 
 :: Table of Contents
  
 RESOURCE Links
 ::  Similar in PUBMED
 ::  Search Pubmed for
 ::  Search in Google Scholar for
 ::Related articles
 ::  [PDF Not available] *
 ::  Citation Manager
 ::  Access Statistics
 ::  Reader Comments
 ::  Email Alert *
 ::  Add to My List *
* Registration required (free) 

  IN THIS Article
 ::  Abstract
 ::  Introduction
 ::  Case report
 ::  Discussion

 Article Access Statistics
    Viewed7341    
    Printed207    
    Emailed2    
    PDF Downloaded0    
    Comments [Add]    
    Cited by others 1    

Recommend this journal


 


 
Year : 1989  |  Volume : 35  |  Issue : 2  |  Page : 116-7

Laparoscopic retrieval of transmigrated IUDS (report of 3 cases).




Correspondence Address:
A M Virkud


Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 0002533611

Rights and PermissionsRights and Permissions


 :: Abstract 

Three cases in whom transmigrated IUDs were removed with operative laparoscope are presented.


Keywords: Adult, Female, Foreign Bodies, surgery,Human, Intrauterine Devices, adverse effects,Intrauterine Devices, Copper, adverse effects,Laparoscopy, Peritoneal Cavity, Uterine Perforation, etiology,Uterine Rupture, etiology,


How to cite this article:
Virkud A M, Shah S K. Laparoscopic retrieval of transmigrated IUDS (report of 3 cases). J Postgrad Med 1989;35:116

How to cite this URL:
Virkud A M, Shah S K. Laparoscopic retrieval of transmigrated IUDS (report of 3 cases). J Postgrad Med [serial online] 1989 [cited 2023 Oct 1];35:116. Available from: https://www.jpgmonline.com/text.asp?1989/35/2/116/5718





 :: Introduction Top


Laparoscopy has been used for the diagnosis of perforated or transmigrated intra-utetrine contraceptive devices (IUD). In experienced hands, the operative laparoscope can also be used for their retrieval, thus avoiding exploratory laparotomy. Three case reports of perforated IUDs removed by Laparoscopy at B. Y. L. Nair Hospital are reported here.


 :: Case report Top


Case 1:

Mrs. K. S., 28 year old second para, presented with menorrhagia following a Lippes' loop inserted seven months ago. On per speculum examination, loop threads could not be seen; sounding of the uterine cavity was negative. X-rays taken with uterine sound (AP and lateral view) showed the 'opened out' loop lying outside and posterior to the uterus in an upside down position. Laparoscopy done by the author revealed the IUD attached to the posterior surface of the uterus with few flimsy avascular adhesions.

The IUD was grasped with prongs of a band applicator and on giving a sharp pull it was separated from the uterus. The operative scope was then withdrawn till the IUD was held firmly between the prongs and edge of the trocar; then the whole assembly (trocar and scope) was removed. The IUD was thus recovered intact with the threads attached and an exploratory laparotomy was avoided.

Case 2:

Mrs. S, a 23 year old 1st para reported with complaints of leucorrhea and backache. She had a Copper T inserted following an MTP done 3 months ago. Per speculum examination showed a cervical erosion and non-specific vaginitis; loop threads were not seen. On sounding, the loop could be felt on the posterior wall, but could not be removed. X-ray pelvis AP and lateral view with uterine sound showed the loop lying in an oblique position above the tip of the uterine sound. A hysteroscopy combined with Laparoscopy was performed. Hysteroscopy done with CO2 hysteroflator showed only the ball of the vertical stem of CuT near the left cornual end; no threads were seen. Laparoscopy showed the CuT perforating the posterior wall on the left side. There were no adhesions. It was removed with the prongs of a band applicator as in the previous case. A thorough curettage failed to recover the missing threads.

Case 3:

Mrs. M.S., a 33 year old multipara was referred from urology OPD with an IVP done to rule out renal stone. The X-ray showed a CuT lying obliquely over the right sacro-iliac synchondrosis. On enquiry, she confessed that she had a loop inserted 4 years ago following an MTP; however, she had it removed about 2 years ago She was not shown the loop after removal. Laparoscopy done with an operative scope revealed the loop lying on the right pelvic wall. There were dust a few flmsy adhesions between the loop and the parietal peritoneum. The IUD was caught with the prongs of a band applicator and a few gentle pulls were given to break the adhesions. It was then removed as in the previous cases.


 :: Discussion Top


It is evident from the above case reports that operative laparoscope can be successfully used for removal of transmigrated or perforated intra-uterine devices. This excploratory laparotomy can be avoided.





This article has been cited by
1 Laparoscopic removal of fish bone
Cheah WK, Fan MJM, Goh PMY
SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES. 1999; 9 (3): 223-225
[Pubmed]



 

Top
Print this article  Email this article
Previous article Next article
Online since 12th February '04
© 2004 - Journal of Postgraduate Medicine
Official Publication of the Staff Society of the Seth GS Medical College and KEM Hospital, Mumbai, India
Published by Wolters Kluwer - Medknow