Journal of Postgraduate Medicine
 Open access journal indexed with Index Medicus & ISI's SCI  
Users online: 2137  
Home | Subscribe | Feedback | Login 
About Latest Articles Back-Issues Articlesmenu-bullet Search Instructions Online Submission Subscribe Etcetera Contact
 
  NAVIGATE Here 
  Search
 
 :: Next article
 :: Previous article 
 :: Table of Contents
  
 RESOURCE Links
 ::  Similar in PUBMED
 ::  Search Pubmed for
 ::  Search in Google Scholar for
 ::Related articles
 ::  Article in PDF (310 KB)
 ::  Citation Manager
 ::  Access Statistics
 ::  Reader Comments
 ::  Email Alert *
 ::  Add to My List *
* Registration required (free) 

  IN THIS Article
 ::  Abstract
 ::  Intracranial pre...
 ::  Jugular venous o...
 ::  Near infrared sp...
 ::  Brain tissue oxi...
 ::  Microdialysis
 ::  Transcranial dop...
 ::  Electrophysiology
 ::  Multimodality mo...
 ::  References
 ::  Article Figures
 ::  Article Tables

 Article Access Statistics
    Viewed22901    
    Printed933    
    Emailed56    
    PDF Downloaded941    
    Comments [Add]    
    Cited by others 28    

Recommend this journal


 


 
REVIEW ARTICLE
Year : 2002  |  Volume : 48  |  Issue : 3  |  Page : 218-25

Monitoring the injured brain in the intensive care unit.


Department of Neuro Critical Care, Addenbrooke's Hospital, Cambridge, UK.

Correspondence Address:
A K Gupta
Department of Neuro Critical Care, Addenbrooke's Hospital, Cambridge, UK.

Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 12432204

Rights and PermissionsRights and Permissions


 :: Abstract 

The primary aim of managing patients with acute brain injury in the intensive care unit is to minimise secondary injury by maintaining cerebral perfusion and oxygenation. The mechanisms of secondary injury are frequently triggered by secondary insults, which may be subtle and remain undetected by the usual systemic physiological monitoring. Continuous monitoring of the central nervous system in the intensive care unit can serve two functions. Firstly it will help early detection of these secondary cerebral insults so that appropriate interventions can be instituted. Secondly, it can help to monitor therapeutic interventions and provide online feedback. This review focuses on the monitoring of intracranial pressure, blood flow to the brain (Transcranial Doppler), cerebral oxygenation using the methods of jugular bulb oximetry, near infrared spectroscopy and implantable sensors, and the monitoring of function using electrophysiological techniques.


Keywords: Brain Injuries, complications,diagnosis,Brain Ischemia, diagnosis,etiology,Cerebrovascular Circulation, physiology,Electrophysiology, Female, Glasgow Coma Scale, Human, Injury Severity Score, Intensive Care, methods,Intensive Care Units, Intracranial Hypertension, diagnosis,etiology,Male, Monitoring, Physiologic, methods,Oximetry, methods,Prognosis, Risk Assessment, Sensitivity and Specificity, Spectrophotometry, Infrared, methods,Ultrasonography, Doppler,


How to cite this article:
Gupta A K. Monitoring the injured brain in the intensive care unit. J Postgrad Med 2002;48:218

How to cite this URL:
Gupta A K. Monitoring the injured brain in the intensive care unit. J Postgrad Med [serial online] 2002 [cited 2023 Mar 25];48:218. Available from: https://www.jpgmonline.com/text.asp?2002/48/3/218/97


The pathophysiological mechanisms which cause brain injury are complex.[1] While continued research in the basic and clinical sciences is making these mechanisms more clearly understood, with current knowledge it is clear that there is little that we can do to reverse the primary damage caused by an insult. However, one of the major factors influencing outcome in patients with acute brain injury is the additional brain damage caused by secondary cerebral insults such as hypoxia and ischaemia.[2],[3] These secondary insults may cause permanent neurological damage and worsening of outcome if undetected and untreated. The purpose of continuous monitoring of the brain in the critical care unit is to detect these secondary insults, allowing for a more informed approach to treatment.

Although serial cranial imaging such as computerised tomography (CT) or functional magnetic resonance imaging (fMRI)) provides useful information, they are neither continuous nor bedside monitors.

Continuous invasive arterial blood pressure monitoring in addition to pulse oximetry, temperature, end tidal carbon dioxide and urine output should be included as part of standard general monitoring of brain injured patients. In addition, techniques specific to the central nervous system are also required. The most common and easily performed clinical monitor is the Glasgow Coma Score, which provides a universally adopted means of measuring central nervous system (CNS) depression.

Brain specific methods of monitoring reflect pressure within the cranial cavity (intracranial pressure, ICP), changes in brain oxygenation and metabolism (jugular venous oxygen saturation, near infrared spectroscopy, brain tissue monitoring, cerebral haemodynamics (transcranial Doppler) and electrical activity of the CNS. This review will give an outline of these specific methods of monitoring.


  ::   Intracranial pressure monitoring Top


Intracranial pressure (ICP) is defined as the pressure within the rigid cranial vault relative to atmospheric pressure. Normal intracranial pressure ranges between 5-15 mmHg, and has two components -– a vasogenic (vascular) component and a cerebrospinal fluid (CSF) component.

Measurement of ICP allows:

1. Continuous monitoring of pressure changes within the intracranial cavity. Acute rises in ICP occur when the compensatory mechanism which control ICP (e. g. CSF production and outflow, changes in cerebral blood flow and volume) are exhausted, and a small rise in intracranial volume results in a large rise in ICP [Figure - 1]. Pressures > 20mmHg are regarded as abnormal and usually requires intervention to reduce ICP.

2. Analysis of the intracranial pressure waveform. The pulse waveform of ICP provides information about the transmission of arterial pulse pressure through the arterial walls to the CSF space. As Cerebral Perfusion Pressure (CPP) decreases, the wall tension in reactive brain vessels decreases. This in turn increases transmission of the arterial pulse to ICP. Therefore when cerebral vessels are normally reactive, a decrease in CPP should provoke an increase in the Arterial Blood Pressure to ICP pulse transmission. If this relationship is disturbed the cerebral vessels are no longer pressure-reactive.[4],[5] This is demonstrated in [Figure - 2] showing a vasogenic plateau wave (Lundberg ‘A’ wave), which are waves related to changes in arterial pressure and hyperaemic events.

3. Estimation of cerebral perfusion pressure (CPP), where Mean CPP = Mean Arterial Pressure – ICP.

In the majority of centres, management of acute brain injury is CPP directed (pressure-driven) with some evidence suggesting that optimizing CPP improves outcome.[6]

Methods of Measurement

The most common sites for ICP measurement are intraventricular and intraparenchymal, although extradural and subdural sensors are occasionally used.

Intraventricular drains allow direct measurement of ICP by inserting a catheter into the ventricular system which is connected to an external pressure transducer. These may be inserted at the bedside in ICU or in the operating theatre and have the added advantage of allowing CSF withdrawal when ICP rises. However, insertion of the ventricular catheter may be difficult or impossible in case of advanced brain swelling, and after three days of monitoring the risk of infection increases significantly. In the case of continuous CSF drainage, continuous intraventricular measurement of ICP may become unreliable.

Modern ventricular, subdural or intraparenchymal microtransducers reduce infection rates and have excellent metrical properties.[7] The intraparenchymal systems may be inserted through a support bolt or tunnelled subcutaneously from a burr hole either at the bedside or post craniotomy.

Subdural catheters are easily inserted following craniotomy but measurements are unreliable and liable to blockage. Extradural probes are less reliable and less specific due to uncertainty about the relationship between ICP and pressure in the extradural space.

Intracranial pressure measurement has not been shown in a prospective controlled trial to improve outcome. However it would now be impossible to conduct such a study ethically. Although it is accepted that ICP is essential in management of CPP directed therapy, the appropriate threshold of CPP is still to be determined.


  ::   Jugular venous oximetry Top


Blood from the venous sinuses of the brain drains into the internal jugular vein, and although it was traditionally believed that the majority of venous blood drained into the right internal jugular vein, there is some data to suggest that supratentorial venous drainage is less lateralised than previously thought.[8] Monitoring of oxygen saturation in jugular venous blood gives an estimate of the balance of global oxygen delivery and cerebral metabolism (oxygen consumption).

The technique involves inserting a retrograde catheter into the internal jugular vein and advancing it cephalad beyond the outlet of the common facial vein into the jugular bulb at the base of the skull [Figure - 3]. Correct placement is confirmed when the catheter tip is level with the mastoid air cells on the lateral neck radiograph (level with the bodies of C1/C2). Aspiration of blood from the jugular bulb should ideally be representative of mixed cerebral venous blood. Although there is no evidence that cannulation of the internal jugular vein on one side is any better than the other,[9] it is common practice to cannulate the right internal jugular vein. Measurements of jugular venous oxygen saturation (SjvO2) can be made by intermittent sampling or continuous monitoring after insertion of a fibreoptic catheter.

The normal range for SjvO2 is 60-75%, and desaturations (indicating potential cerebral ischemia) of less than 50% have been associated with a worsened outcome in head injury.[10] [Table - 1] summarises the factors contributing to changes in SjvO2.

Intermittent sampling allows estimation of arteriovenous oxygen difference and lactate, which will help give an indication of global cerebral oxygenation and metabolism. Increases in arteriojugular differences in oxygen content to greater than 9ml/dl also provides a useful marker of inadequate cerebral blood flow (CBF) and may help guide therapy.[11] Continuous SjvO2 monitoring will detect episodes of desaturation associated with raised ICP, hyperventilation therapy, hypotension and cerebral vasospasm. However, up to half of measured desaturations below 50% may be false positives.[10]

The major limitation of SjvO2 monitoring is that it is a global measure of cerebral oxygenation. As a result, smaller areas of ischaemia may not be detected unless of sufficient magnitude to affect global brain saturation. Regional ischaemia may therefore be missed.

Other inaccuracies may occur if the catheter is not accurately placed or if blood sampling is too rapid. The continuous fibreoptic catheters may give inaccurate readings if impacted against the vessel wall or if thrombosis occurs on the catheter tip and the sensor may need frequent recalibrations. Despite these limitations SjvO2 monitoring is an important tool both in the clinical management of acute brain injury and also for studying cerebral physiology.


  ::   Near infrared spectroscopy Top


The principle of Near Infrared Spectroscopy (NIRS) is based upon the fact that light in the near infrared red range (700-1000 nm) can pass through the skin, bone and other tissues relatively easily. When a beam of light is passed through brain tissue, it is both scattered and absorbed [Figure - 4]. The absorption of near infrared light is proportional to the concentration of certain chromophores, notably iron in haemoglobin and copper in cytochrome aa3. Oxygenated haemoglobin (HbO2), deoxygenated haemoglobin (Hb) and cytochrome aa3 have different absorption spectra, depending on the substances’ oxygenation status. Changes of concentration of near infrared light as it passes through these compounds can be quantified using a modified Beer-Lambert law, which describes optical attenuation. The main advantage of NIRS is that it is a non-invasive method of estimating regional changes in cerebral oxygenation. However, the clinical use of NIRS is limited by its inability to differentiate between intracranial and extracranial changes in blood flow and oxygenation which adversely affects the reliability of the readings.[12] The validation of this technique in neuro intensive care still requires further work.


  ::   Brain tissue oximetry Top


Insertion of sensors directly into brain tissue to continuously measure brain tissue oxygenation has gathered considerable interest over the last decade. With recent technological advances, two commercially available sensors have been produced. One sensor measures only brain tissue oxygen tension using a polarographic Clarke type electrode, whilst the other multiparameter sensor measures brain tissue oxygen (PbO2), carbon dioxide (PbCO2) and pH using fibreoptic technology [Figure - 5]. Both of these methods have the ability to measure brain temperature using a thermocouple. Both sensors are approximately 0.5 mm in diameter and can be inserted through a craniotomy intraoperatively or through a specially designed bolt allowing insertion and fixation to the skull in the intensive care unit.

A recent study validating in vivo measurements of the multiparameter sensor against values of cerebral end capillary oxygen tension derived from Positron Emission Tomography found that absolute values of these two variables did not correlate, which was to be expected, although the changes in measured values in response to hyperventilation did correlate.[13] Furthermore there is evidence to show that brain tissue sensors detect changes in regional oxygenation which would otherwise be missed using conventional jugular bulb oximetry.[14] With a mounting body of clinical data from many centres and the limitations of jugular bulb oximetry described above, the use of implanted brain tissue sensors to give a continuous measure of regional brain oxygenation is increasingly regarded as a useful and reliable monitoring tool by many authorities. This technique is a focal method of monitoring tissue oxygenation, and although ideally should be placed in the penumbral area, it is often difficult to place it with such accuracy at the present time.


  ::   Microdialysis Top


The technique of cerebral microdialysis allows continuous and on-line monitoring of changes in brain tissue chemistry. In common with brain tissue oxygenation monitoring, microdialysis involves inserting a fine catheter (diameter 0.62 mm) into the brain. The catheter is lined with a polyamide dialysis membrane and is perfused with a physiological solution (e.g. Ringer’s) at ultra-low flow rates (0.1-2.0 mcl/min) using a precision pump, allowing measurement of the concentration of chemicals in the extracellular space of the brain. Molecules below the cut-off size of the semipermeable membrane (approximately 20000 Daltons) diffuse from the extracellular space into the perfusion fluid, which is then collected into vials that are changed every 10 to 60 minutes. The collected dialysate is then analysed by sensitive assays.

In theory, any substance small enough to diffuse through the dialysis membrane can be measured,[15] but the key substances can be categorised as follows:

1. Energy related metabolites e.g. glucose, lactate, pyruvate, adenosine, xanthine. The lactate/pyruvate ratio is a better marker of ischaemia, than lactate alone.[16]

2. Neurotransmitters - glutamate, aspartate, GABA

3. Markers of tissue damage and inflammation - glycerol, potassium, cytokines

4. Exogenous substances - administered drugs

Continuous on line measurement of glucose, lactate, pyruvate, glutamate and glycerol can be achieved using a CMA600 microdialysis analyser (CMA Microdialysis, Stockholm, Sweden). Good correlation has been shown between the CMA600 analyser and the gold standard of High Performance Liquid Chromatography (HPLC).[17]

Cerebral microdialysis has been applied to patients in many different clinical situations including head injury, subarachnoid haemorrhage, epilepsy, ischaemic stroke, tumours and during neurosurgery.[18] In patients with severe head injury derangements in metabolism have been associated with reductions in brain glucose and elevation of the lactate:pyruvate ratio during periods of intracranial hypertension and cerebral ischaemia. Wide variations in the concentration of the excitatory amino acids glutamate and aspartate have also been detected, with extremely high and toxic levels in secondary ischaemia and contusions. During aneurysm surgery, changes in concentration of glucose, lactate, pyruvate and glutamate have been demonstrated during cerebro-spinal fluid drainage, brain retraction and temporary clipping. Epileptic foci in the temporal lobe are associated with elevated glutamate and reduced ?-amino-butyric acid levels prior to seizures and increases in both amino acids during seizures.

An evolving application of microdialysis is its use in measuring drug concentrations in brain parenchyma, and potentially using this method to directly administer drugs into targeted areas.[19] Although the use of microdialysis as a reliable tool for routine clinical practice in neuro intensive care is not established as yet, its role as a research tool is undeniable.


  ::   Transcranial doppler ultrasonography Top


Transcranial Doppler Ultrasonography (TCD) is a non-invasive monitor providing indirect information of cerebral blood flow in one of the major arteries in the base of the brain. A 2 MHz pulsed ultrasound signal is transmitted through the skull (usually through the temporal bone) and using the Doppler shift principle measures red cell flow velocity (FV). Insonation of one of the arteries (most commonly the middle cerebral artery (MCA)) produces an arterial waveform giving information on systolic, diastolic and mean blood flow velocity [Figure - 6]. The mean flow velocity (FVmean) is a weighted mean velocity that takes into account the different velocities of the formed elements in the blood vessel insonated and normally has a mean value of 55 + 12cm/s in the MCA. Changes in FV correlate closely with changes in CBF provided the angle of insonation (the angle between the axis of the vessel and the ultrasound beam) and the diameter of the vessel insonated remain constant.[20],[21] The shape of the envelope of the Doppler spectrum from peak systolic flow to end diastolic flow with each cardiac cycle is known as the waveform pulsatility. In the absence of vessel stenosis or vasospasm or changes in arterial blood pressure or blood rheology, the pulsatility reflects the distal cerebrovascular resistance. This resistance is usually quantified by the Pulsatility Index (PI or Gosling index) = (FVsys - FVdias)/ FVmean. The PI (normal PI ranges from 0.6 to 1.1) has been shown to correlate better with CPP than ICP.

One of the most useful applications of TCD in neurointensive care is in the diagnosis of high velocity states such as cerebral vasospasm or hyperaemia. The differentiation between the two conditions is important in order to target therapy more appropriately. Flow velocities of greater than 120 cm/s after insonating the MCA is considered significantly high.[22] If the ratio of MCA flow velocity to extracranial internal carotid flow velocity (Lindegaard ratio) is greater than 3, vasospasm is the likely diagnosis,[23] whereas if mean MCA FV >120cm/s and the Lindegaard ratio is less than 3, hyperaemia is diagnosed.

TCD when compared with angiography for the middle cerebral artery shows high levels of specificity and positive predictive value for vasospasm. Following traumatic brain injury, TCD monitoring can be used to observe changes in FV, waveform pulsatility and for testing cerebral vascular reserve. Currently a lot of work is being done to investigate the application of TCD as a non-invasive estimation of ICP or CPP. Although this work is in its early stages there has been limited success in correlating CPP derived from TCD with invasive CPP measurement.[24] In addition, by continuous recording of the FVmca, the autoregulatory ‘threshold’ or ‘break point’ (the CPP at which autoregulation fails) can be easily detected, providing a target CPP value for treatment.. Autoregulation can be tested by response of the TCD trace to vasopressor infusion (static autoregulation) or thigh tourniquet deflation (dynamic).


  ::   Electrophysiology Top


An electroencephalogram (EEG) represents spontaneous electrical activity of the cerebral cortex and is generated mainly by summation of excitatory and inhibitory post-synaptic potentials of cortical neurones. It does not reflect activity in subcortical levels, cranial nerves or the spinal cord. The electrical activity is recorded from scalp electrodes placed according to the 10-20 Electrode System [Figure - 7] - where the interelectrode distances are either 10% or 20% of the patient’s head circumference, interaural distance, or nasion-inion distance. The electrical signal is amplified, filtered and then displayed as either 8 or 16 channels (8 channels per hemisphere) to give an accurate representation of electrical activity throughout the cortex. EEG activity is usually interpreted in terms of frequency [Table - 2], amplitude, and location (focal or generalised activity).

To facilitate continuous EEG monitoring several automated EEG processing systems have been developed.

1. Power spectral analysis allows fast Fourier transformation of small intervals of EEG to provide a graphical representation of the relative power content of the various frequency bands in each segment of EEG. These spectral diagrams are then stacked to show how the frequency of the EEG alters with time to produce a compressed spectral array. This spectral analysis can also give a single number (either the mean frequency or the frequency below which 95% of the signal lies) that can be tracked over time.

2. Cerebral Function Monitor (CFM) provides a single trace of total power varying with both amplitude and frequency of raw EEG data.

3. Cerebral Function Analysing Monitor (CFAM) is a similar method, which produces displays of both amplitude and frequency and avoids the loss of information when these are processed together.

The EEG is an important and frequently used tool in the investigation and management of epilepsy which aids in confirming the diagnosis, classify the seizure disorder and identify a focal or lateralised epileptogenic source. Early detection of subclinical seizures with EEG in ICU may help reduce mortality and morbidity in status epilepticus.[25]

Continuous EEG monitoring is also useful in detecting ischaemic cerebral events, including vasospasm following sub-arachnoid haemorrhage (SAH) and intracranial hypertension after head injury.[26]

Certain EEG features are associated with a poor outcome and in some cases may be useful in predicting eventual survival. Various grading systems have been developed based on the presence or absence of these features [Table - 3]. Grades I and II are associated with a good outcome, grade III an intermediate prognosis, grades IV and V are associated with a very poor outcome.

Specific conditions relevant to ICU can be diagnosed using EEG monitoring. For example, temporal paroxysmal lateralising electrical discharges are indicative of Herpes Simplex encephalitis, whilst paroxysmal bursts of 2-3 Hz indicate subacute sclerosing panencephalitis.

In sedated patients, EEG may help in detection of focal neurological disease especially in those who cannot be examined fully and in patients too unwell to undergo neuroradiological imaging. Metabolic suppression using intravenous anaesthetic agents may be monitored using CFM, where burst suppression or isoelectricity is a useful endpoint to obtain maximal suppression of cortical electrical activity.


  ::   Multimodality monitoring Top


The concept of multimodal monitoring involves continuous monitoring of more than one parameter using two or more of the techniques described above. This helps to overcome the limitations of each individual method of monitoring thereby enabling more accurate analysis of changes in the measured parameters. For example, a detected rise in ICP may be due to a rise in cerebral blood volume due to hyperaemia or cytotoxic oedema as a result of ischaemia. Multimodal monitoring helps in differentiating the two causes of a rise in ICP as shown in [Figure - 8]. [Figure:8a] demonstrates a rise in ICP associated with a rise in flow velocity measured by TCD, indicating hyperaemia. However, in [figure:8b] the rise in ICP is associated with a simultaneous fall in flow velocity and jugular bulb oximetry, indicating hypoperfusion. It can be seen that without the other modalities in addition to ICP, the primary cause of the ICP rise may have been misinterpreted resulting in inappropriate intervention.

All of the monitoring systems described above have the potential to give artefactual data to a varying degree, which may be difficult to identify in isolation. Although the multimodal approach increases the complexity and the potential to generate artefacts in the system, since each modality measures independent variables, the artefacts are unlikely to occur at the same time in each modality. The use of more than one method of monitoring will therefore help differentiate real events from an artefact.

The use of multimodal monitoring has a number of disadvantages. Firstly, the more monitors used, the more expensive the system becomes. Secondly, large amounts of data will be generated from each monitor. This makes the system complex, requiring a technician or highly trained nursing staff to maintain the various modalities and ensure that the monitors are correctly placed at all times. This may be difficult when monitoring for a number of days in the intensive care unit. In addition, the data generated needs to be acquired in a format that allows quick and easy analysis. Computer support for downloading the data is an essential part of the system, further adding to the cost and labour intensity.

Multimodal monitoring undoubtedly enhances the accuracy of interpretation of events and may help in targeting treatment more appropriately. As experience in these techniques grow it will become apparent which of these modalities are required to provide the most accurate reflection of intracranial events and monitor subsequent therapy.[27],[28]

 
 :: References Top

1.Siesjo BK Pathophysiology and treatment of focal cerebral ischaemia. Parts I Pathophysiology. J Neurosurg 1992;77:169-84.   Back to cited text no. 1    
2.Chestnut RM, Marshall SB, Piek J, Blunt BA, Klauber MR, Marshall LF. Early and late systemic hypotension as a frequent and fundamental source of cerebral ischemia following severe brain injury in the Traumatic Coma Data Bank. Acta Neurochir (Wien) 1993;59 (suppl):121-25.  Back to cited text no. 2    
3.Jones PA, Andrews PJD, Midgley S, Anderson SI, Piper IR, Tocher JL, et al. Measuring the burden of secondary insults in head injured patients during intensive care. J Neurosurg Anesthesiol 1994;6:4-14.  Back to cited text no. 3    
4.Czosnyka M, Guazzo E, Whitehouse H, Smielewski P, Czosnyka Z, Kirkpatrick P, et al. Significance of intracranial pressure waveform analysis after head injury. Acta Neurochir (Wien) 1996;138:531-42  Back to cited text no. 4    
5.Czosnyka M, Smielewski P, Kirkpatrick P, Laing RJ, Menon D, Pickard JD. Continuous assessment of the cerebral vasomotor reactivity in head injury. Neurosurgery 1997;41:11-9.  Back to cited text no. 5    
6.Rosner MJ, Daughton S. Cerebral perfusion pressure management in head injury. J Trauma 1990;30:933-41.  Back to cited text no. 6    
7.Czosnyka M, Czosnyka Z, Pickard JD: Laboratory testing of three intracranial pressure microtransducers: Technical report. Neurosurgery 1996;38:219-24.  Back to cited text no. 7    
8.Metz C, Holzschuh M, Bein T, Woertgen C, Rothoerl R, Kallenbach B, et al. Monitoring of cerebral oxygen metabolism in the jugular bulb: reliability of unilateral measurements in severe head injury. J Cereb Blood Flow Metab 1998;18:332-43.  Back to cited text no. 8    
9.Stocchetti N, Paparella A, Bridelli F, Bacchi M, Piazza P, Zuccoli P. Cerebral venous oxygen saturation studied with bilateral samples in the internal jugular veins. Neurosurgery 1994;34:38-44.  Back to cited text no. 9    
10.Sheinberg M, Kanter MJ, Robertson CS, Constant CF, Narayan RK, Grossman RG. Continuous monitoring of jugular venous oxygen saturation in head injured patients. J Neurosurg 1992;76:212-71.  Back to cited text no. 10    
11.Cruz J. The first decade of continuous monitoring of jugular bulb oxyhemoglobin saturation: management strategies and clinical outcome. Crit Care Med 1998;26:344-51.  Back to cited text no. 11    
12.Owen-Reece H, Smith M, Elwell CE, Goldstone JC. Near infrared spectroscopy. Br J Anaesth 1999;82:418-26.   Back to cited text no. 12    
13.Gupta AK, Hutchinson PJ, Fryer T, Al-Rawi P, Parry DA, Minhas PS, et al. Measurement of Brain Tissue Oxygenation Performed using Positron Emission Tomography scanning to validate a novel monitoring method. J Neurosurg 2002;96:263-8.  Back to cited text no. 13    
14.Gupta AK, Hutchinson PJ, Al-Rawi P, Gupta S, Swart M, Kirkpatrick PJ, et al. Measurement of brain tissue oxygenation compared with jugular venous oxygen saturation for monitoring cerebral oxygenation after traumatic brain injury. Anesth Analg 1999;88:549-53.   Back to cited text no. 14    
15.Johnston AJ, Gupta AK. Advanced Monitoring in Neuro ICU: Microdialysis. Curr Opin Crit Care Med. (In Press)  Back to cited text no. 15    
16.Persson L, Valtysson J, Enblad P, Warme PE, Cesarini K, Lewen A, et al. Neurochemical monitoring using intracerebral microdialysis in patients with subarachnoid hemorrhage. J Neurosurg 1996;84:606-16.  Back to cited text no. 16    
17.Hutchinson PJ, O’Connell MT, Al-Rawi PG, Maskell LB, Kett-White R, Gupta AK, et al. Clinical cerebral microdialysis: a methodological study. J Neurosurg 2000;93:37-43.   Back to cited text no. 17    
18.Peerdeman SM, Girbes AR, Vandertop WP. Cerebral microdialysis as a new tool for neurometabolic monitoring. Intensive Care Med 2000; 26:662-9.  Back to cited text no. 18    
19.Muller M. Science, Medicine and the future: Microdialysis. BMJ 2002; 324:588-91.  Back to cited text no. 19    
20.Bishop CCR, Powell S, Rutt D, Browse NL. Transcranial Doppler measurement of the middle cerebral blood flow velocity: a validation study. Stroke 1986;17:913-5.  Back to cited text no. 20    
21.Dahl A Russell D, Nyberg-Hansen R, Rootwelt K. A comparison o regional cerebral blood flow and middle cerebral artery blood flow velocities: simultaneous measurements in healthy subjects. J Cereb Blood Flow Metab 1992;12: 1049-54.  Back to cited text no. 21    
22.Aaslid R, Huber P, Nornes H. Evaluation of cerebrovascular spasm with Transcranial Doppler ultrasound. J Neurosurg 1984;60:1:37-41.  Back to cited text no. 22    
23.Lindegaard KF, Nornes H, Bakke SJ, Sortberg W, Nakstad P. Cerebral vasospasm after subarachnoid haemmorhage investigated by means of Transcranial Doppler ultrasound. Acta Neurochirurgica (Wein) 1988;42:81-4.  Back to cited text no. 23    
24.Schmidt EA, Czosnyka M, Gooskens I, Piechnik SK, Matta BF, Whitfield PC. Preliminary experience of the estimation of cerebral perfusion pressure using transcranial doppler ultrasonography. J Neurol Neurosurg Psychiatr 2001;70:198-204.  Back to cited text no. 24    
25.Young GB, Jordan KG, Doig GS. An assessment o nonconvulsive seizures in the intensive care unit using continuous EEG monitoring:an investigation of variables associated with mortality. Neurology 1996; 47:83-9.  Back to cited text no. 25    
26.Jordan KG Continuous EEG monitoring in the neurosciences intensive care unit and emergency department. J Clin Neurophysiol 1999; 16:14-39.  Back to cited text no. 26    
27.Kirkpatrick PJ, Czosnyka M, Pickard JD. Multimodal monitoring in neurointensive care. J Neurol Neurosurg Psychiatr 1996;60:131-9.  Back to cited text no. 27    
28.Czosnyka M, Kirkpatrick PJ, Pickard JD. Multimodal monitoring and assessment of cerebral haemodynamic reserve after severe head injury. Cerebrovasc Brain Metab Reviews 1996;8:273-95.  Back to cited text no. 28    


    Figures

[Figure - 1], [Figure - 2], [Figure - 3], [Figure - 4], [Figure - 5], [Figure - 6], [Figure - 7], [Figure - 8], [Figure - 9]

    Tables

[Table - 1], [Table - 2], [Table - 3]

This article has been cited by
1 Pervasive real-time biomedical monitoring system
Cheriyan, A.M., Jarvi, A., Kalbarczyk, Z., Iyer, R.K., Watkin, K.L.
2nd International Conference on Biomedical and Pharmaceutical Engineering, ICBPE 2009 - Conference Proceedings. 2009; (art5384101)
[Pubmed]
2 Pervasive embedded systems for detection of traumatic brain injury
Cheriyan, A.M., Jarvi, A.O., Kalbarczyk, Z., Gallagher, T.M., Iyer, R.K., Watkin, K.L.
Proceedings - 2009 IEEE International Conference on Multimedia and Expo, ICME 2009. 2009; (art5202849): 1704-1707
[Pubmed]
3 Pervasive embedded real time monitoring of EEG & SpO2
Cheriyan, A.M., Kalbarczyk, Z., Iyer, R.K., Jarvi, A.O., Gallagher, T.M., Watkin, K.L.
2009 3rd International Conference on Pervasive Computing Technologies for Healthcare - Pervasive Health 2009, PCTHealth 2009. 2009; (art5173599)
[Pubmed]
4 Predicting awakening of unconscious patients with EEG nonlinear analysis
Wu, D., Sun, Z., Ke, S.
Chinese Journal of Rehabilitation Medicine. 2009; 24(11): 969-972
[Pubmed]
5 Near infrared technology in neuroscience: Past, present and future
Calderon-Arnulphi, M., Alaraj, A., Slavin, K.V.
Neurological Research. 2009; 31(6): 605-614
[Pubmed]
6 Evaluation of conscious disturbance with EEG nonlinear analysis in patients with stroke
Wu, D.-Y., Liu, L., Song, J.-J., Yuan, Y., Li, G.-Q., Cai, G., Song, W.-Q., Wang, M.-B.
Chinese Journal of Cerebrovascular Diseases. 2008; 5(9): 385-389
[Pubmed]
7 Optic nerve sonography in the diagnostic evaluation of adult brain injury
Soldatos T, Karakitsos D, Chatzimichail K, et al.
CRITICAL CARE. 2008; 12(3): art no R67
[Pubmed]
8 The effect of pneumoperitoneum and Trendelenburg position on acute cerebral blood flow-carbon dioxide reactivity under sevoflurane anaesthesia
Choi, S.H., Lee, S.J., Rha, K.H., Shin, S.K., Oh, Y.J.
Anaesthesia. 2008; 63(12): 1314-1318
[Pubmed]
9 Quality assurance indicators for risk management in the follow-up of medical care received by acute ischemic stroke patients | [Des indicateurs de qualité et de gestion des risques pour suivre la prise en charge hospitalière des accidents vasculaires cérébraux]
Le Barbier, M., Deltour, S., Crozier, S., Léger, A., Pires, C., Rufat, P., Samson, Y., Bourdillon, F.
Sante Publique. 2008; 20(3): 225-237
[Pubmed]
10 Acute symptomatic seizures in CNS infection
Kim, M.A., Park, K.M., Kim, S.E., Oh, M.K.
European Journal of Neurology. 2008; 15(1): 34-37
[Pubmed]
11 Jugular venous oximetry | [Saturación de oxígeno del bulbo de la yugular]
Carrillo-Esper, R., Carrillo-Córdova, L.D.
Revista Mexicana de Anestesiologia. 2007; 30(4): 225-232
[Pubmed]
12 Scanning system for noninvasive optoacoustic monitoring of blood oxygenation in the internal jugular vein
Brecht, H.-P., Prough, D.S., Petrov, Y.Y., Patrikeev, I., Esenaliev, R.O.
Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2007; 6437: A 643704
[Pubmed]
13 Noninvasive measurement of intracranial pressure: Is it possible?
Czarnik T, Gawda R, Latka D, et al.
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE. 2007; 62 (1): 207-211
[Pubmed]
14 Multimodality monitoring in neurocritical care
Wartenberg KE, Schmidt JM, Mayer SA
CRITICAL CARE CLINICS. 2007; 23 (3): 507-538
[Pubmed]
15 Monitoring brain tissue oxymetry: Will it change management of critically ill neurologic patients?
Mazzeo, A.T., Bullock, R.
Journal of the Neurological Sciences. 2007; 261(1-2): 1-9
[Pubmed]
16 In vivo monitoring of blood oxygenation in large veins with a triple-wavelength optoacoustic system
Brecht HP, Prough DS, Petrov YY, et al.
OPTICS EXPRESS. 2007; 15 (24): 16261-16269
[Pubmed]
17 Early detection of life-threatening intracranial haemorrhage using a portable near-infrared spectroscopy device
Kessel B, Jeroukhimov I, Ashkenazi I, et al.
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED. 2007; 38 (9): 1065-1068
[Pubmed]
18 Compressed EEG pattern analysis for critically ill neurological-neurosurgical patients
Shah AK, Agarwal R, Carhuapoma JR, et al.
NEUROCRITICAL CARE. 2006; 5 (2): 124-133
[Pubmed]
19 Validation of a noninvasive neonatal optical cerebral oximeter in veno-venous ECMO patients with a cephalad catheter
Rais-Bahrami K, Rivera O, Short BL
JOURNAL OF PERINATOLOGY. 2006; 26 (10): 628-635
[Pubmed]
20 Intracerebral microdialysis and intracranial compliance monitoring of patients with traumatic brain injury
Salci, K., Nilsson, P., Howells, T., Ronne-Engstróm, E., Piper, I., Contant Jr., C.F., Enblad, P.
Journal of Clinical Monitoring and Computing. 2006; 20(1): 25-31
[Pubmed]
21 Global systems for monitoring cerebral hemodynamics in the neurocritical patient: basic concepts, controversies and recent advances in measuring jugular bulb oxygenation
Poca MA, Sahuquillo J, Monforte R, Vilalta A
NEUROCIRUGIA. 2005; 16 (4): 301-322
[Pubmed]
22 New technologies in the intensive care unit: A cautionary tale
Goldstein, B.
Pediatric Critical Care Medicine. 2005; 6(3): 378-379
[Pubmed]
23 Monitoring intracranial pressure, perfusion and metabolism
Pattinson, K., Wynne-Jones, G., Imray, C.H.E.
Continuing Education in Anaesthesia, Critical Care and Pain. 2005; 5(4): 130-133
[Pubmed]
24 Recent advances in regional cerebral monitoring in the neurocritical patient: Brain tissue oxygen pressure monitoring, cerebral microdialysis and near-infrared spectroscopy
Poca, M.A., Sahuquillo, J., Mena, M.P., Vilalta, A., Riveiro, M.
Neurocirugia. 2005; 16(5): 385-409
[Pubmed]
25 Multimodal monitoring in the neurological intensive care unit
De Georgia MA, Deogaonkar A
NEUROLOGIST. 2005; 11 (1): 45-54
[Pubmed]
26 Changes in the intracranial rheoencephalogram at lower limit of cerebral blood flow autoregulation
Bodo M, Pearce FJ, Baranyi L, et al.
PHYSIOLOGICAL MEASUREMENT. 2005; 26 (2): S1-S17
[Pubmed]
27 Effects of milrinone on jugular bulb oxygen saturation and cerebrovascular carbon dioxide reactivity in patients undergoing coronary artery bypass graft surgery
Oh, Y.J., Kim, S.H., Shinn, H.K., Lee, C.S., Hong, Y.W., Kwak, Y.L.
British Journal of Anaesthesia. 2004; 93(5): 634-638
[Pubmed]
28 Cerebrovascular reactivity: rat studies in rheoencephalography
Bodo M, Pearce FJ, Armonda RA
PHYSIOLOGICAL MEASUREMENT. 2004; 25 (6): 1371-1384
[Pubmed]



 

Top
Print this article  Email this article
Previous article Next article
Online since 12th February '04
© 2004 - Journal of Postgraduate Medicine
Official Publication of the Staff Society of the Seth GS Medical College and KEM Hospital, Mumbai, India
Published by Wolters Kluwer - Medknow